how to test a deep well pump motor

As a deep well pump supplier, I’ve spent thousands of hours troubleshooting motor failures that could’ve been caught with simple, reliable testing. Deep well pump motors are designed to operate in extreme conditions—submerged hundreds of feet below ground, exposed to variable water pressure, and running nonstop for weeks or months at a time. Rushing through pre-installation tests or skipping routine checks not only leads to avoidable downtime for our customers, but it’s also a waste of money for something that’s preventable. Let me walk you through the exact testing process we use at our warehouse when preparing units for shipment, and what we recommend customers do before powering their system up for the first time. Deep Well Pump

First, before you even hook anything up, start with a visual and physical inspection. It sounds basic, but I’ve seen dozens of motors arrive at job sites with cracked insulation frayed on power leads, or small debris caught in the impeller housing that would turn into a problem the second the power was flipped on. For a deep well pump motor, the stator windings are hermetically sealed, so any compromise to the outer casing or cable jacket is a red flag. I always run my hands along the entire length of the power cable, from the terminal box at the top of the motor down to the splice if there is one, looking for nicks, gouges, or signs of water intrusion. If your motor is designed for submersible use, the casing should have a smooth, unblemished exterior—any dents could have damaged the internal seals, which means it’s not safe to test under pressure yet. I also check the impeller: spin it by hand to make sure it moves freely, no grinding or sticking. If it’s tight, there’s likely debris in the volute, which you’ll want to clear before moving to electrical tests.

Next up, insulation resistance testing, often called a megger test. This is the single most important test for a deep well pump motor, because it measures how well the windings are insulated against current leaking to the motor’s casing or ground. A lot of people use a standard multimeter for basic checks, but a megohmmeter (megger) is non-negotiable here. For most submersible deep well motors, the recommended test voltage is 500V, unless the motor is smaller than 1HP, in which case 250V works. The rule of thumb for pass/fail is: the insulation resistance should be at least 1 megohm, and it should not drop below 1 megohm for every 1000V of operating voltage. Wait, let me clarify that—if your motor is rated for 230V, the minimum acceptable insulation resistance is 0.23 megohms? No, no, that’s a common mistake. The correct industry standard for submersible motors is that insulation resistance at room temperature should be a minimum of 1 megohm, and for motors over 1000V, it’s 1 megohm per 1000V. I always mention to customers that if your reading is below 0.5 megohms, that motor is not safe to run—it’s likely absorbed moisture, especially if it’s been stored outdoors near water, or has a small leak in the casing. If you get a low reading, you can try drying the motor: submerge it in a tub of clean water (yes, fully submerged) for 24-48 hours, or blow dry the windings with low-pressure hot air, but don’t overheat it—submersible motor windings can take temperatures up to 150°F, but nothing higher. After drying, retest; if it still reads low, the winding insulation is compromised, and you’ll need a replacement.

Once insulation checks out, move to a phase continuity test. This makes sure that each of the three power leads (for three-phase motors, which are most common for deep well pumps over 1HP) is connected properly, and there are no broken or shorted windings. You’ll use a multimeter set to the ohms setting. For a good three-phase motor, each of the three windings should have roughly the same resistance. For example, if one winding reads 12 ohms, the other two should be within 5-10% of that number. If one is drastically higher, that’s an open winding; if one is zero or near zero, that’s a shorted winding. Both mean the motor needs repair or replacement. For single-phase motors, it’s a little different: you’ll have two leads for the main winding and one for the start winding. The main winding will have a lower resistance than the start winding, and the total resistance between the common lead and the run lead should be the sum of the main and start winding resistances. If that doesn’t add up, there’s a fault in the winding. I’ve found that a lot of installation mistakes here are mislabeling leads when splicing, so double-check your manufacturer’s wiring diagram before doing this test—getting the phases wrong can burn out a brand new motor in minutes.

With electrical continuity checked, the next step is a no-load test. This is when you power the motor (with the pump disconnected from the water, if possible, or in a sump of water if it’s submersible) and run it without any load on the impeller. This lets you check for unusual noise, vibration, and measure voltage and current draw, which tells you a lot about the motor’s health. First, make sure the motor is fully submerged if it’s a submersible type—running it dry even for 30 seconds can overheat the stator and destroy the winding insulation. Connect your multimeter to measure the incoming voltage on each phase (for three-phase) and make sure it matches the motor’s rated voltage within 5%—too low or too high voltage will cause abnormal current draw. For example, if your motor is rated for 230V, don’t test it on 200V or 250V. Once power is on, listen for any grinding, humming, or rattling. A healthy submersible motor will run quietly, with only a low, steady hum. If it sounds like it’s struggling, that’s usually a bad winding or a misaligned impeller. Next, measure the current draw on each phase. The no-load current (the current when the motor is spinning without load) should be roughly 20-30% of the motor’s full-load current rating. If the no-load current is much higher, that means the motor has a shorted winding or is mechanically binding. If it’s much lower, that could be an open winding. I always tell customers to log these numbers—full-load current is listed on the motor’s nameplate, so you can compare the no-load and eventual full-load current to catch issues early. One trick I use for no-load testing: run the motor for 10-15 minutes, let it warm up, then retest insulation resistance. It should still be above 1 megohm; if it drops after running, that’s a sign of gradual insulation breakdown, which will get worse over time.

After no-load testing, the final pre-installation test is a pressure test for submersible motors. This is specific to deep well pumps that are fully submerged— the seal that keeps water out of the motor housing is critical, and a leak here will destroy the motor. To do this, you’ll need a pressure testing kit designed for deep well motors (or a simple air compressor with a pressure gauge). First, seal the motor’s cable entry and any vents (check your manufacturer’s instructions—some motors have a pressure-relief valve, so make sure to plug that temporarily). Then, apply air pressure of 5-10 PSI to the motor’s casing, and submerge the entire motor in a tub of clean water. Watch for bubbles—if you see any, that’s a leak. Hold the pressure for 10 minutes; if the pressure drops more than 1 PSI during that time, there’s a leak that needs to be fixed before installation. I’ve seen too many customers skip this step, only to pull the pump back out of the well a few weeks later because water got inside the motor. It’s an extra 20 minutes of work, but it saves you from a costly well dig and pump replacement.

Once the motor is installed and hooked up to the pump, you’ll want to do a post-installation test to confirm it’s working correctly. Turn the power on, let the system run for 30 minutes, then check the water flow rate. The flow rate should match the manufacturer’s specifications for your pump model—if it’s too low, that could mean the impeller is clogged, the motor is running at the wrong speed, or there’s a leak in the discharge pipe. Also, check the motor’s surface temperature (for non-submersible motors) or listen for overheating—if it’s too hot to touch without burning your hand, that’s a sign of overload. For submersible motors, you can use a thermal camera to check the casing temperature, which should stay around 10-15°F above ambient water temperature when running properly.

I’ve been in the deep well pump industry for 12 years, and the most common mistakes I see are skipping insulation tests, miswiring phases, and not pressure testing submersible motors. A little testing upfront saves you from losing a full day of work, or worse, having to replace a $2,000 motor that could’ve been avoided. If you’re preparing to install a deep well pump, or if you’ve tested your motor and found issues that don’t make sense, don’t hesitate to reach out to our team to discuss your needs. We can help you walk through any test, troubleshoot any faults, or get a replacement unit ready for shipment quickly.

Pressure Gauge References
National Electrical Manufacturers Association (NEMA) Standard MG 1-2021: Motors and Generators
Underwriters Laboratories (UL) Standard 1081: Electric Submersible Pumps for Water Well Systems
Institute of Electrical and Electronics Engineers (IEEE) Standard 43-2020: Recommended Practice for Testing Insulation Resistance of Rotating Machinery


Taizhou Hanner Machinery Co., Ltd.
Taizhou Hanner Machinery Co., Ltd. is one of the leading deep well pump manufacturers and suppliers in China. We warmly welcome you to wholesale hot selling deep well pump from our factory. All customized products are with high quality and competitive price.
Address: Southeast Industrial Accumulation, Songmen Town, Wenling City, Zhejiang, China
E-mail: kathy@cnhanner.com
WebSite: https://www.hannerpump.com/